16
6-560.4
Figure 16.1 - 30°, 60°, and 90° Downward Deflector
Hoods
MOUNTING
HEIGHT
X
Y
Y
Z
Z
X
60 DOWNTURN
30 DOWNTURN
Note:
X = Feet from Heater to Start of Floor Coverage
Y = Feet to End of Floor Coverage
Z = Feet to End of Throw
60
30
30 DOWNTURN
60 DOWNTURN
Figure 16.2 - 30° and 60° Throw/Floor Coverage
Figure 16.3 - 90° Hood Throw/Floor Coverage
30° HOOD 60° HOOD 90° HOOD
Table 16.2 - Deflector Hood General Performance
Data - Model PTP
Note: Refer to Figures 16.2 through 16.3.
PERFORMANCE DATA - HOODS FOR PROPELLER MODELS
Model
Size
Airflow
Temp
Rise
Mounting
Height
Blade
Angle
30° Hood 60° Hood 90° Hood
X Y Z X Y Z S
(cfm)
(°F) (ft) (°) (ft) (ft) (ft) (ft) (ft) (ft) (ft)
150 2139 53
8 60 15 32 44 0 34 47 23
10 52 13 31 42 0 32 44 21
12 42 12 29 40 0 29 40 19
14 30 10 26 36 0 25 34 18
16 9 7 20 29 0 17 24 17
175 2726 48
8 60 14 32 43 0 33 46 23
10 51 13 30 42 0 31 43 21
12 41 12 28 39 0 28 39 19
14 29 10 25 35 0 24 33 17
16 8 6 17 26 0 14 21 16
200 2780 52
8 59 14 30 42 0 32 44 22
10 49 12 29 40 0 30 41 19
12 39 11 27 37 0 26 36 18
14 24 9 23 33 0 21 30 16
250 3994 47
8 66 19 41 56 0 43 59 32
10 60 18 40 54 0 42 57 29
12 53 17 38 53 0 40 54 26
14 45 15 36 50 0 37 51 24
16 37 14 34 47 0 33 46 23
18 26 12 30 43 0 28 39 21
20 8 7 22 32 0 18 26 20
300 4543 50
8 69 22 45 62 0 48 66 37
10 63 21 44 61 0 47 64 33
12 57 19 43 59 0 45 62 30
14 51 18 42 57 0 43 59 28
16 43 16 40 55 0 40 55 26
18 35 15 37 52 0 36 50 25
20 25 13 33 47 0 31 43 24
22 9 8 25 37 0 21 30 22
350 5278 50
8 67 20 43 58 0 45 62 34
10 61 19 42 57 0 44 60 31
12 55 18 40 55 0 42 58 28
14 48 16 39 53 0 40 54 26
16 40 15 37 51 0 36 50 24
18 30 13 33 47 0 32 44 23
20 17 10 29 41 0 25 35 22
21 2 7 23 34 0 18 26 21
400 5995 51
8 70 24 49 66 0 52 71 41
10 65 22 48 65 0 51
69 37
12 59 21 47 64 0 49 67 34
14 54 20 45 62 0 47 64 31
16 47 18 44 60 0 44 61 29
18 40 17 41 57 0 41 57 27
20 32 15 38 54 0 37 51 26
22 21 13 34 48 0 31 43 25
23 13 11 31 44 0 26 37 24
Comentarios a estos manuales